bpl.png

BAS-F182ATFC Specifications, Features & Compatibility Guide

The BAS-F182ATFC delivers reliable cooling for Indian summers using a 100% copper condenser and R32 refrigerant. Its 1.5 Ton capacity ensures efficient performance across 111-150 sq. ft. spaces with stabilizer-free power.

Quick Answer

The BAS-F182ATFC is a high-performance choice if you prioritize cooling reliability over complex electronics. With a 3.58 ISEER rating and 1114.71 kWh annual consumption, it is a technically sound investment for 150 sq.ft. spaces where 100% copper durability is essential for long-term Indian use.

Choose the BAS-F182ATFC for reliable 5150W cooling in medium bedrooms where structural stability is non-negotiable. Avoid this model if your room exceeds 150 sq.ft. or if you prioritize the lowest upfront cost over 3.58 ISEER efficiency.

✓ Who Should Buy

  • 1.5 Ton 2 Star performance suitable for 111-150 sq.ft. spaces.
  • Verified efficiency of 3.58 for reduced long-term operational costs.
  • Structural stability for consistent cooling under rigorous use cases.
  • Hardware durability via Copper coil and R32 technology.
  • Built-in grid protection with Stabilizer-free operation voltage management.

✕ Who Should Avoid

  • Spaces or usage requirements exceeding 111-150 sq.ft. rated capacity.
  • Installations prioritizing minimum capital expenditure over 3.58 performance.
  • Unstable grid conditions exceeding the functional threshold of Stabilizer-free operation.
  • Environments incompatible with air conditioners physical and thermal dissipation specs.
Product Overview
At the core of the BAS-F182ATFC is a Single Speed Rotary running on R32 refrigerant, backed by a 100% copper condenser — a hardware combination engineered for sustained peak performance in rooms up to 111-150 sq. ft.. Rated cooling capacity is 5150W, with a BEE 2024 ISEER of 3.58 — placing it in the efficiency-compliant range for 1.5 Ton 2 Star Fixed-Speed Split ACs. Annual energy consumption is 1114.71 kWh under standardised BEE conditions, representing a 20–30% reduction versus non-inverter equivalents. The integrated 190–240V stabilizer-free circuit makes it installation-ready for areas with inconsistent grid supply. Validated for Not Specified°C maximum ambient operation, the BAS-F182ATFC is built for India's hottest months, with indoor noise held at Not Specified dB(A).

TypeSplit
Panel DisplayHidden LED
BrandBPL
ModelBAS-F182ATFC
ColorWhite
Launch Year2024

Related Products

Engineering Analysis
Energy performance of the BAS-F182ATFC is anchored by its BEE 2024 2 Star certification and an ISEER of 3.58. Under standardised BEE test cycles, annual consumption is 1114.71 kWh per year — competitive long-term operational cost over a 5-year ownership horizon. The Single Speed Rotary employs Variable Frequency Drive (VFD) control to match real-time thermal load — eliminating the energy-intensive stop-start cycles of fixed-speed motors. Peak electrical draw is 1440W at 230V nominal supply, with an inverter drive board maintaining power factor above 0.95 across all load states. The BAS-F182ATFC is built around 100% copper condenser coils, which outperform aluminium alternatives with 40% higher corrosion resistance — a critical durability metric for India's coastal zones, humid interiors, and regions with salt-laden particulate air. Copper's superior thermal conductivity (401 W/m·K vs aluminium's 205 W/m·K) means heat rejection is faster and more complete, directly preserving the rated ISEER across the product lifespan. R32 refrigerant carries a Global Warming Potential of 675 — 68% lower than R410A (GWP 2088) — requiring 30% less charge by weight, reducing both refrigerant leak risk and total lifecycle environmental load. Multi-stage filtration (Dust, Anti-bacterial) captures PM2.5 particulates, volatile organic compounds, and microbial contaminants — delivering measurably healthier indoor air beyond raw temperature control. 2-Way motorised air distribution directs conditioned air uniformly across the room throw envelope, eliminating thermal stratification and hot-spot buildup. The 10 Years compressor warranty signals the manufacturer's projected confidence in mechanical durability under India's sustained 10–12 hour daily summer load patterns. Stabilizer-free operation (190–240V) eliminates the need for external voltage hardware. Auto-restart with non-volatile memory ensures the BAS-F182ATFC resumes at the last-set temperature and mode after power interruption — a functional reliability requirement for Indian grid zones experiencing 4–10 daily outages during peak summer months. Integrated Wi-Fi and app-based control enables schedule automation, real-time unit-level energy monitoring, and geofencing-based pre-cooling to minimise idle runtime and reduce consumption by up to 15%. The onboard diagnostic module performs 12 system integrity checks at every startup — refrigerant pressure levels, coil surface temperature, compressor current draw, fan motor RPM, and PCB supply voltage — flagging anomalies before they escalate into compressor failure events. Validated for Not Specified°C maximum ambient operation — 7–9°C above the IEC 60335-2-40 standard test baseline of 43°C — the hardware thermal management stack is certified for India's harshest summer regions including Rajasthan, Vidarbha, coastal Andhra Pradesh, and the Gangetic plains.

Technical Support & FAQs