Honeywell Air Touch V2

Honeywell Air Touch V2: High-Efficiency 350 CADR HEPA + Activated Carbon for 450 Sq.Ft.

The Honeywell Air Touch V2 delivers a robust Clean Air Delivery Rate (CADR) of 350 m³/hr to facilitate rapid air exchange cycles. Engineered for spaces up to 450 sq.ft., it effectively manages pollutant concentrations through its high-density filtration bank. The integrated HEPA filter achieves a 99.97% removal rate for microscopic particulates down to the 0.3-micron threshold. With a variable acoustic profile ranging from 32-54 dB, it provides consistent environmental remediation across different fan velocities.

Quick Answer

The Honeywell Air Touch V2 is recommended for rooms up to 450 sq.ft. where high-volume air turnover is required. It features a professional-grade 3-stage filtration system—Pre-Filter, HEPA, and Activated Carbon—ideal for those prioritizing mechanical filtration efficiency (99.97% at 0.3 microns) over smart sensor automation.

✓High-Performance 350 m³/hr CADR for rapid volumetric air cleaning.
✓99.97% Filtration Efficiency for sub-micron particulate matter (0.3 microns).
✓Three-Stage Mechanical Filtration: Pre-filter, HEPA, and Activated Carbon.
✓Optimized for 450 sq.ft. residential or commercial floor plans.
✓Acoustically tuned operation between 32 dB (low) and 54 dB (turbo).

The Air Touch V2 is a 'Performance-First' purifier designed for users who value mechanical filtration surface area over smart-home connectivity.

✓ Who Should Buy

  • •Users needing 350 m³/hr throughput for 450 sq.ft. rooms.
  • •Individuals seeking 99.97% HEPA filtration for allergy relief.
  • •Those who prefer simple manual controls without app-dependency.

✕ Who Should Avoid

  • •Users requiring real-time PM2.5 AQI monitoring displays.
  • •Those looking for automated 'Auto-Mode' based on air sensors.
  • •Users requiring Wi-Fi or Smart Assistant integration.
Product Overview
The Honeywell Air Touch V2 is a precision-engineered air purification unit designed for high-throughput air remediation. Unlike sensor-driven automated units, this model focuses on the mechanical integrity of its 350 m³/hr CADR delivery system. It covers a substantial 450 sq.ft. area, making it suitable for master bedrooms and living rooms. The filtration stack is built around a true HEPA core that captures 99.97% of allergens and fine dust. A dedicated activated carbon layer is integrated to adsorb VOCs and odors, while the pre-filter extends the lifespan of the secondary stages by trapping large 10-micron plus debris. With its rear-inlet design and upward discharge, it maximizes the Coanda effect to circulate purified air across the specified 450 sq.ft. footprint. The unit operates via manual speed controls, allowing for precise user-defined air exchange rates based on environmental needs.

Brandhoneywell
Model NameAir Touch V2
Model NumberV2
CategoryAir Purifier
Sub CategoryRoom Air Purifier
Purifier TypeHEPA + Activated Carbon
Installation TypeFloor Standing
Coverage Area Sqft450
Room SizeMedium
UsageHome
Launch Year2019
Model Year2019
Country Of OriginChina
ManufacturerHoneywell International Inc.

Related Products

Engineering Analysis
From an environmental engineering perspective, the Honeywell Air Touch V2 utilizes a high-static pressure fan to overcome the resistance of a 3-stage filter medium. The 350 m³/hr CADR rating indicates that the unit can cycle the air in a 450 sq.ft. room with a standard ceiling height approximately 4.5 times per hour. The HEPA filter efficiency of 99.97% at 0.3 microns is critical for capturing PM2.5 and viral nuclei, which rely on Brownian motion for interception within the filter fibers. The lack of a PM2.5 sensor necessitates a manual operational logic; the user must determine fan speeds (Low, Med, High) based on perceived air quality or specific timed intervals. This manual approach ensures consistent motor torque and eliminates the 'cycling' fluctuations often seen in automated sensors that react to momentary localized dust spikes. The acoustic engineering limits noise to 54 dB at peak 350 m³/hr output, which is acceptable for daytime use, while the 32 dB low setting maintains 99.97% filtration efficiency at a reduced CFM. The rear-inlet architecture requires strategic placement at least 12 inches from walls to maintain the structural integrity of the intake airflow and prevent motor strain.

Technical Support & FAQs