Schneider 2P 125A 30mA RCCB (16970) – Commercial

The Schneider Electric 16970 is a 125A 2-pole (2P) Type A RCCB manufactured in France for demanding commercial applications.This device operates at 230V and provides dedicated earth leakage protection with a 30mA sensitivity, ensuring rapid disconnection in the event of a fault.

Quick Answer

Yes, the Schneider 16970 is an indispensable safety component for significant commercial installations. If your distribution board requires a robust 2P 125A RCCB for main incomer protection at 230V, its 30mA sensitivity guarantees essential human safety by rapidly isolating earth faults. Choose it for uncompromised personnel protection in demanding Indian commercial setups.

Stops accidental electrocution in commercial zones — 30mA sensitivity triggers instantaneous shutdown within 40ms at 5x Idn.
Rated for high-capacity 125A circuits — the 16970 model serves as a heavy-duty main incomer for 230V systems.
Protects internal components against high-energy surges — 6kV impulse withstand voltage ensures performance during lightning or grid spikes.
Compact 36mm width for efficient board layout — 2-module design fits perfectly on a standard 35mm DIN rail.
Survives extreme heat and fire conditions — the UL94 V-0 flammability-rated casing passes 960°C glow wire testing.
Certified for long-term mechanical reliability — tested for 20,000 mechanical cycles and 10,000 electrical cycles.

Electrical contractors and facility managers prioritizing human safety in large 230V commercial distribution boards should opt for the Schneider 16970. This 2P 125A RCCB is overkill for residential use, designed specifically for demanding main incomer earth leakage protection.

Product Overview
The Schneider Electric 16970 is a 125A 2-pole (2P) Type A RCCB manufactured in France for demanding commercial applications. This device operates at 230V and provides dedicated earth leakage protection with a 30mA sensitivity, ensuring rapid disconnection in the event of a fault. As a main incomer component, it is designed for integration into distribution boards where reliable human safety and fire protection are required.

Related Products

Engineering Analysis
The 30mA tripping sensitivity is essential for personnel protection as it disconnects the circuit in ≤300ms, well within the safety window to prevent cardiac arrest. Its 125A rated current is supported by a 1250A making and breaking capacity, allowing it to handle substantial switching loads at the main entry point. The 2P configuration provides critical neutral isolation, ensuring that leakage current is fully interrupted across both active conductors.