No Image Available

ABB 2P 40A 300mA RCCB (FW202) – Residential

The ABB FW202 is a 40A, 2-pole (2P) Residual Current Circuit Breaker (RCCB) specifically engineered for residential main incomer applications.

Quick Answer

Absolutely, the ABB FW202 2P 40A 300mA RCCB is ideal for robust fire protection at your residential main incomer in India. Its 300mA sensitivity effectively prevents fire risks from residual currents, avoiding nuisance tripping in homes with multiple sub-circuits. Crucially, as a non-overload protected device, pair it with a backup MCB for comprehensive electrical safety. This makes the FW202 a vital component for secure Indian households.

Safeguards property against leakage-induced fires — 300mA sensitivity triggers shutdown within 300ms.
Rated Current of 40A — supports standard residential loads while operating within 180–264V range.
Durable construction for years of safety — mechanical endurance rated at 10,000 cycles.
10kA breaking capacity — manages high fault levels to prevent equipment destruction during shorts.
Compact 36mm DIN rail mounting — occupies only 2 modules in your distribution board.
Flame-retardant housing — withstands 850°C glow wire tests and meets UL94 V2 standards.

This ABB FW202 RCCB is a definitive purchase for homeowners prioritizing advanced fire protection at their main electrical incomer, especially to mitigate cumulative leakage risks. However, those expecting a standalone device with built-in overload protection should look elsewhere, as this specific model requires a separate backup MCB for full circuit protection.

Product Overview
The ABB FW202 is a 40A, 2-pole (2P) Residual Current Circuit Breaker (RCCB) specifically engineered for residential main incomer applications. This Type AC device operates within a 180–264V range to provide dedicated fire protection by monitoring for a 300mA residual current threshold. Manufactured in Italy, it is a non-overload protected device that must be paired with a backup MCB to ensure complete circuit safety.

Related Products

Engineering Analysis
Selecting a 300mA sensitivity is vital for fire prevention at the main incomer where lower sensitivities might cause nuisance tripping from cumulative leakage across multiple sub-circuits. The 10kA conditional short circuit rating ensures the device maintains integrity during high-fault events, while the 4kV impulse withstand voltage protects against atmospheric surges. Its 2P configuration with solid neutral is essential for safely isolating residential 230V systems during a trip event.

Technical Support & FAQs