Havells DHRGCRFF100063 Specifications, Features & Compatibility Guide

The Havells DHRGCRFF100063 is a 63A 4P (4P) voltage operated ELCB specifically engineered for residential safety. This device acts as a primary earth leakage monitor, triggering an immediate disconnect when it senses a 100mA residual current. It is installed at the main incomer to provide total system isolation during fault conditions.

Quick Answer

Yes, the Havells DHRGCRFF100063 is an excellent choice if paramount residential electrical safety is your priority. Specifically designed for main incomer installation, its 63A 4P configuration and precise 100mA earth leakage detection offer superior fire protection and system isolation. Opt for this device to ensure verified efficiency and long-term peace of mind in your Indian home's electrical setup.

The Havells DHRGCRFF100063 is purpose-built for homeowners seeking robust 100mA earth leakage protection at their main incomer. Avoid if your requirements exceed residential capacity or if capital expenditure is prioritized over verified long-term efficiency and critical safety features.

✓ Who Should Buy

  • performance suitable for residential spaces.
  • Verified efficiency of standard rating for reduced long-term operational costs.
  • Structural stability for consistent cleaning under rigorous use cases.
  • Hardware durability via premium components and advanced technology.
  • Built-in grid protection with Standard power cycle voltage management.

✕ Who Should Avoid

  • Spaces or usage requirements exceeding residential rated capacity.
  • Installations prioritizing minimum capital expenditure over high-efficiency performance.
  • Unstable grid conditions exceeding the functional threshold of Standard power cycle.
  • Environments incompatible with electrical safety devices physical and thermal dissipation specs.
Product Overview
The Havells DHRGCRFF100063 is a 63A 4P (4P) voltage operated ELCB specifically engineered for residential safety. This device acts as a primary earth leakage monitor, triggering an immediate disconnect when it senses a 100mA residual current. It is installed at the main incomer to provide total system isolation during fault conditions.

Related Products

Engineering Analysis
The 100mA sensitivity level is specifically chosen to provide a balance between preventing electrical fires and avoiding nuisance tripping in residential circuits. A 630A making and breaking capacity allows the device to safely handle the high inrush currents typical of domestic appliance startups. The 4P configuration is essential for 240V systems as it switches the neutral line to ensure zero potential on all load-side conductors during a trip.

Technical Support & FAQs