ABB DS201-C40/0.03 Specifications, Features & Compatibility Guide
✓ Who Should Buy
- • performance suitable for residential spaces.
- •Verified efficiency of standard rating for reduced long-term operational costs.
- •Structural stability for consistent cleaning under rigorous use cases.
- •Hardware durability via premium components and advanced technology.
- •Built-in grid protection with Standard power cycle voltage management.
✕ Who Should Avoid
- •Spaces or usage requirements exceeding residential rated capacity.
- •Installations prioritizing minimum capital expenditure over high-efficiency performance.
- •Unstable grid conditions exceeding the functional threshold of Standard power cycle.
- •Environments incompatible with electrical safety devices physical and thermal dissipation specs.
Product Overview
The ABB DS201-C40/0.03 is a 40A, 2-pole (1P+N) Residual Current Breaker with Overcurrent protection designed for residential final circuits. Manufactured in Italy, this device provides essential protection against earth leakage, overloads, and short circuits in a compact 2-module width. It operates at 230V with an instantaneous tripping mechanism to ensure maximum safety for household users.
Related Products
Electrical Safety Devices Service Experts
Verified Stabilizer & Electrical Safety professionals for installation, repair and servicing.
N
NSR ELECTRICALS AND BUILDING SOLUTIONS
20 yrs experience
LB Nagar, Nagole
S
Sai Electricals Services
10 yrs experience
Nagole, LB Nagar +6 more
K
KS Electricals
4 yrs experience
AC Guards
D
Diwakar Electricals & Engineeing
3 yrs experience
Secunderabad, Uppal +9 more
Engineering Analysis
The 30mA Type AC sensitivity is calibrated specifically for personnel protection, tripping within ≤40ms at 5× Idn to prevent lethal current flow through the human body. The 6kA breaking capacity, combined with Energy Limiting Class 3, minimizes the thermal stress on cables during high-energy faults common at the main incomer. Its 2P switched neutral configuration is vital for residential safety, ensuring total isolation of faulty circuits from the electrical supply.
Technical Support & FAQs
Engineering Analysis
The 30mA Type AC sensitivity is calibrated specifically for personnel protection, tripping within ≤40ms at 5× Idn to prevent lethal current flow through the human body. The 6kA breaking capacity, combined with Energy Limiting Class 3, minimizes the thermal stress on cables during high-energy faults common at the main incomer. Its 2P switched neutral configuration is vital for residential safety, ensuring total isolation of faulty circuits from the electrical supply.