No Image Available

Legrand 4P 16A 30mA RCBO (DX3) – Residential

The Legrand DX3 RCBO AC Type FP 16A 30mA is an integrated safety solution for residential final circuits. This 4P (4-pole) device combines the functions of an RCCB and an MCB, providing comprehensive earth leakage and 10kA short circuit protection. It is specifically designed for 415V Indian residential systems to ensure human and installation safety.

Quick Answer

Yes, invest in the Legrand 4P 16A 30mA DX3 RCBO for uncompromised electrical safety in your Indian residence. It's ideal for new installations or upgrades, offering combined 30mA earth leakage and 10kA short-circuit protection, simplifying your distribution board while safeguarding lives and appliances from dangerous faults. This ensures compliance and peace of mind.

Prevents fatal shocks in domestic environments through precise 30mA earth leakage detection.
Rated current of 16A ensures reliable power delivery for standard residential lighting and power loops.
Guarantees long-term mechanical reliability with a tested endurance of 10,000 cycles.
Breaking capacity of 10kA manages high-intensity short circuit faults without catastrophic device failure.
Utilizes halogen-free, self-extinguishing materials that pass the 850°C glow wire test.
Compact 4-module width (72mm) allows for space-saving installation on standard 35mm DIN rails.

This Legrand DX3 4P 16A 30mA RCBO is a crucial upgrade for Indian residential safety, perfectly combining 30mA human life protection and 10kA short-circuit breaking capacity. It's essential for new builds or circuit modernizations, offering streamlined, superior protection where uncompromising safety and efficiency are paramount.

Product Overview
The Legrand DX3 RCBO AC Type FP 16A 30mA is an integrated safety solution for residential final circuits. This 4P (4-pole) device combines the functions of an RCCB and an MCB, providing comprehensive earth leakage and 10kA short circuit protection. It is specifically designed for 415V Indian residential systems to ensure human and installation safety.

Related Products

Engineering Analysis
The 30mA sensitivity is the critical threshold for human life protection, as it trips the circuit in ≤40ms at 5x Idn to prevent ventricular fibrillation. A 10kA breaking capacity is essential for modern distribution boards to safely extinguish high-energy arcs during major faults. Four-pole protection with a switched neutral ensures that the return path is fully isolated during a trip event, preventing potential back-feed hazards.

Technical Support & FAQs