No Image Available

Schneider 2P 63A 30mA RCCB (A9R41263) – Home

The Schneider Electric A9R41263 is a 2P 63A RCCB with 30mA sensitivity designed for direct integration into single-phase 230V residential systems.

Quick Answer

Yes, you should definitely consider the Schneider A9R41263 if your priority is advanced human-life protection for a modern Indian home. Its 30mA sensitivity reliably safeguards against electric shock, while the 63A rating comfortably manages typical heavy domestic loads. This RCCB is ideal for ensuring safety and compliance within 230V single-phase systems, even with voltage fluctuations.

Prevents lethal electrocution by detecting 30mA leakage current and disconnecting the circuit instantly.
10kA conditional short circuit capacity ensures the device remains functional during massive electrical surges.
Rapidly clears faults to stop electrical fires with a tripping time of less than 40ms at 5x rated residual current.
Mechanical endurance of 20,000 cycles provides decades of reliable manual switching and testing functionality.
Halogen-free construction ensures no toxic fumes are released even during a 960°C glow wire test.
6kV impulse withstand voltage protects your home electronics from damage during sudden atmospheric voltage spikes.

The Schneider A9R41263 is a vital safety upgrade for Indian homeowners. Delivering 30mA human-life protection, it handles heavy 63A domestic loads on 230V single-phase systems. Ensure reliable safeguarding against earth leakages, even with grid variations.

Product Overview
The Schneider Electric A9R41263 is a 2P 63A RCCB with 30mA sensitivity designed for direct integration into single-phase 230V residential systems. This Type AC device monitors current balance to provide primary earth leakage protection, ensuring immediate disconnection when faults are detected. It operates reliably within a voltage range of 184–264V to maintain safety despite common Indian grid fluctuations.

Related Products

Engineering Analysis
The 30mA sensitivity level is specifically engineered to provide human-life protection by tripping before leakage current reaches the threshold of heart fibrillation. While the 63A rated current supports heavy domestic loads, the 10kA conditional short circuit rating ensures the internal components withstand high-energy faults when paired with an MCB. The 2P configuration provides critical neutral isolation, ensuring the entire 230V circuit is safely cleared during an earth leakage event.

Technical Support & FAQs