No Image Available

Schneider 3P+N 25A 300mA RCBO (A9D7725) –

The Schneider Electric A9D7725 is a 25A 3P+N RCBO specifically engineered for industrial main incomer applications requiring high-sensitivity fire protection.

Quick Answer

Yes, purchase the Schneider A9D7725 RCBO if your industrial facility requires robust, combined protection for 3-phase systems. Its 25A 3P+N configuration and 300mA Type AC sensitivity are specifically engineered for high-risk areas needing superior fire and electrical fault prevention, a critical safety standard for many Indian industries. It integrates overload, short-circuit, and earth leakage into one compact unit, ensuring comprehensive safety and compliance.

Protects your facility from fire hazards — 300mA residual current sensitivity trips the circuit within ≤300ms at 1x Idn.
High 6kA breaking capacity — ensures the device can safely interrupt significant fault currents without internal damage.
Guarantees long-term mechanical reliability — rated for 20,000 cycles to reduce maintenance overhead in industrial environments.
C-curve tripping characteristic — allows for standard industrial inductive loads while maintaining a 25A continuous rating.
Operates safely in demanding thermal conditions — UL94 V0 flammability rating and 960°C glow wire test compliance ensure housing integrity.
3P+N switched neutral configuration — provides total circuit disconnection for 400V systems during instantaneous trip events.

This Schneider A9D7725 RCBO is essential for Indian industrial sites prioritizing advanced 3-phase system safety with 300mA fire protection. Avoid if your application is residential or requires only basic overload protection; its specialized features and cost are tailored for complex industrial main incomer demands.

Product Overview
The Schneider Electric A9D7725 is a 25A 3P+N RCBO specifically engineered for industrial main incomer applications requiring high-sensitivity fire protection. This 400V device integrates earth leakage, overload, and short-circuit protection into a single 4-module width unit, ensuring comprehensive safety for complex 3-phase systems. Operating at a 50Hz frequency, it utilizes Type AC residual current sensing to detect 300mA leakages before they can ignite flammable materials.

Related Products

Engineering Analysis
The Type AC sensing mechanism is calibrated for a 300mA threshold, making it essential for fire prevention where leakage currents might otherwise go undetected by standard 25A breakers. Its 6kA breaking capacity and Class 3 energy limiting performance allow it to safely manage high-energy faults at the distribution source. The 3P+N design with a switched neutral is critical for industrial settings, ensuring that neutral faults are isolated alongside the three phases to prevent voltage imbalances.

Technical Support & FAQs