No Image Available

Siemens 2P 6A 30mA RCBO (5SU13541RC06) – Residential

The Siemens 5SU13541RC06 is a 6A, 2P (1P+N) RCBO designed specifically for residential final circuits to provide simultaneous protection against overloads and earth leakages.

Quick Answer

Yes, the Siemens 5SU13541RC06 is an excellent choice for Indian residential final circuits. Its 30mA sensitivity ensures immediate human safety against dangerous shocks, while the 10kA breaking capacity provides superior protection for modern homes against high fault currents. This 2P device integrates critical overload and earth leakage safeguards into one compact unit, streamlining your electrical panel and enhancing overall home safety.

Immediate shock protection — 30mA sensitivity trips the circuit within ≤300ms at 1x Idn.
10kA short-circuit breaking capacity ensures the device remains functional after handling high-energy faults.
Compact space-saving design — only 2 modules (36mm) wide for efficient distribution board management.
4kV impulse withstand voltage protects the internal components against sudden atmospheric voltage spikes.
Simplified troubleshooting — integrated trip indicator and blue test button allow for quick fault identification.
Durable electrical performance — rated for 4,000 electrical cycles and 10,000 mechanical operations for long-term reliability.

This Siemens 5SU13541RC06 RCBO is ideal for homeowners prioritizing paramount safety and advanced protection for their residential electrical systems in India. If you require a combined 6A overload and 30mA earth leakage solution with high 10kA breaking capacity for a modern home, this device is a compelling, actionable investment for peace of mind.

Product Overview
The Siemens 5SU13541RC06 is a 6A, 2P (1P+N) RCBO designed specifically for residential final circuits to provide simultaneous protection against overloads and earth leakages. This Type AC device operates at a rated voltage of 230V and features 30mA sensitivity to ensure human safety during direct contact. It integrates short circuit and overload protection into a single 180g unit, eliminating the need for a separate backup MCB.

Related Products

Engineering Analysis
The 30mA sensitivity is critical for residential final circuits as it trips within ≤300ms to stop current flow before it causes cardiac arrest. A 10kA breaking capacity is essential for modern homes where potential fault currents can exceed standard 6kA ratings. The 2P configuration with a switched neutral ensures that the entire circuit is safely isolated during a fault, preventing neutral-to-earth voltage issues.

Technical Support & FAQs