No Image Available

Siemens 2P 16A 30mA ELCB (5SU1356-6KK13) – residential

The Siemens 5SU1356-6KK13 is a 16A 2P voltage-operated ELCB designed specifically for residential final circuit protection. Operating within a wide 184–264V range, this 30mA Type A device detects hazardous earth leakage to prevent fire and shock. It is installed on 35mm DIN rails and occupies only 36mm of space in your distribution board.

Quick Answer

Prioritize safety with the Siemens 5SU1356-6KK13 ELCB. This 16A, 30mA Type A device is purpose-built for Indian residential final circuits, offering critical human life protection by swiftly detecting hazardous earth leakages. Its broad operating voltage range (184-264V) ensures reliable performance amidst common grid fluctuations, making it an indispensable component for preventing electrical shocks and fires.

Provides immediate human safety — 30mA Type A sensitivity detects minimal leakage currents.
10kA conditional short circuit strength ensures the unit remains functional after clearing severe faults.
Protects internal components from voltage spikes — 4kV impulse withstand voltage rating.
250A making and breaking capacity handles temporary high-current surges without damaging contacts.
Compact 36mm width saves space — fits easily into standard 2-module DIN rail 35mm slots.
Flame-retardant housing ensures fire safety — UL94 V 0 flammability rating and 960°C glow wire test.

This Siemens 5SU1356-6KK13 ELCB is essential for Indian residential homeowners and electricians prioritizing human life safety in final circuits. It’s ideal for new installations or upgrading existing distribution boards with reliable 30mA earth leakage protection for 16A loads. Avoid if your application demands industrial-grade higher current or different sensitivity ELCBs.

Product Overview
The Siemens 5SU1356-6KK13 is a 16A 2P voltage-operated ELCB designed specifically for residential final circuit protection. Operating within a wide 184–264V range, this 30mA Type A device detects hazardous earth leakage to prevent fire and shock. It is installed on 35mm DIN rails and occupies only 36mm of space in your distribution board.

Related Products

Engineering Analysis
A 30mA sensitivity is essential for human life protection as it interrupts the circuit within 300ms at 1x rated leakage current. The 10kA conditional short circuit rating allows this unit to withstand significant faults when paired with a backup MCB, while the 2-pole configuration ensures both phase and neutral are isolated during a trip. With a making and breaking capacity of 250A, the device manages heavy residential switching loads without contact welding.

Technical Support & FAQs